EER, CEER, and SEER2: Air Conditioner Efficiency Ratings Explained

Understanding air conditioner efficiency ratings is straightforward once you know their formulas: EER measures steady-state cooling at 95°F, CEER adds standby power consumption for window units, and SEER2 accounts for seasonal weather swings in central and mini-split systems. Every one-point increase in CEER cuts a window air conditioner's electricity consumption by 8% to 10%, saving roughly $15 to $35 each summer depending on your local electricity rates.

Key takeaways

  • Energy Efficiency Ratio (EER) equals cooling output in BTUs divided by electrical power in watts measured at a single steady-state test point (95°F outside, 80°F inside).
  • Combined Energy Efficiency Ratio (CEER) is the official federal standard for window and room air conditioners, integrating active cooling efficiency with off-cycle standby power.
  • Seasonal Energy Efficiency Ratio 2 (SEER2) updated federal testing in 2023 under DOE Appendix M1, increasing external static duct pressure to reflect real-world installation conditions.
  • Inverter-driven variable-speed window air conditioners achieve CEER ratings between 14.0 and 15.7, compared to 11.0 to 12.0 for traditional single-speed compressors.

EER: The foundation of cooling efficiency

The oldest and simplest efficiency metric is the Energy Efficiency Ratio (EER). The formula is direct: EER = BTUs of cooling per hour ÷ Electrical watts consumed. For example, a standard 8,000 BTU window air conditioner that draws 727 watts of electrical power while running has an EER of 11.0 (8,000 ÷ 727 = 11.0).

EER testing takes place under fixed laboratory conditions: 95°F outdoor ambient temperature, 80°F indoor dry-bulb temperature, and 50% relative humidity. While EER provides a reliable snapshot of peak summer performance during the hottest afternoon of the year, it fails to account for part-load conditions or power drawn when the compressor is off.

CEER: The modern standard for window air conditioners

To address the limitations of EER, the U.S. Department of Energy established the Combined Energy Efficiency Ratio (CEER) as the mandatory rating standard for room air conditioners. CEER incorporates active cooling mode, standby power drawn while waiting for remote control signals, and inactive power drawn when the unit is plugged in during the off-season.

Because modern air conditioners spend hundreds of hours in standby mode with digital displays and Wi-Fi modules energized, CEER ratings are slightly lower than traditional EER numbers. An air conditioner with an EER of 12.1 typically earns a CEER rating of 11.8.

Under current federal standards, standard window units must achieve a minimum CEER between 9.0 and 11.0 depending on capacity and chassis type. Premium inverter units reach CEER ratings above 15.0, cutting annual electricity consumption by up to 35%. You can browse certified ratings across hundreds of units in our room air conditioner catalog or inspect the most efficient room air conditioners leaderboard.

SEER vs. SEER2: What changed in federal standards

While CEER governs room units, central air conditioning and ductless mini-split systems are rated under the Seasonal Energy Efficiency Ratio (SEER). SEER measures total cooling delivered across a representative seasonal temperature distribution (from 65°F to 104°F) divided by total watt-hours consumed.

On January 1, 2023, the Department of Energy replaced legacy SEER with SEER2 under test standard Appendix M1. The legacy SEER test procedure used an external static duct pressure of 0.1 to 0.2 inches of water column (in. w.c.), which dramatically underestimated the duct resistance found in real homes.

SEER2 increased test static pressure to 0.5 in. w.c., representing real ductwork. Because blowers must work harder against realistic resistance, SEER2 ratings are roughly 4.5% to 5% lower than legacy SEER numbers for the exact same physical equipment. A legacy 14.0 SEER system translates to roughly 13.4 SEER2.

How to calculate annual operating costs from CEER

You can calculate the estimated annual running cost of any window air conditioner using the federal test schedule (750 cooling hours per year) with this simple formula:

  • Annual kWh = (Cooling BTUs ÷ CEER rating) × 750 hours ÷ 1,000
  • Annual Cost = Annual kWh × (Your Local Electric Rate in cents ÷ 100)

For a 10,000 BTU air conditioner with a standard CEER of 11.0: (10,000 ÷ 11.0) × 750 ÷ 1,000 = 682 kWh per season. At 18.31¢ per kWh, that unit costs $124.87 to run. A high-efficiency inverter model with a CEER of 15.0 uses only 500 kWh, costing $91.55 per season, saving $33.32 every summer. For sizing advice, see our room AC BTU sizing guide.

FAQ

What is the difference between EER and CEER? EER measures cooling efficiency only while the compressor is actively running at 95°F. CEER includes active cooling plus the standby electricity drawn when the unit is turned off or cycling.

What is a good CEER rating for a window air conditioner? A CEER rating of 11.5 to 12.5 is good for standard units. Inverter-driven variable-speed window air conditioners achieve exceptional CEER ratings between 14.0 and 15.7.

Why are SEER2 ratings lower than older SEER ratings? SEER2 testing increased static duct pressure from 0.1 to 0.5 inches of water column to reflect real-world duct airflow resistance. The tougher test lowers the numerical rating by roughly 4.5%.

How much money does a higher CEER rating save? Upgrading from a CEER 10.0 unit to an inverter CEER 15.0 model cuts seasonal cooling electricity use by 33%, saving roughly $30 to $65 per unit each summer depending on your climate and electric rate.

Federal appliance test procedures and efficiency definitions are published in 10 CFR Part 430 by the U.S. Department of Energy.